WORLD’S COATING INNOVATOR™
OFFICIAL MANUFACTURER’S WEBSITE
WORLD’S COATING INNOVATOR™
OFFICIAL MANUFACTURER’S WEBSITE

Architecture

There’s a range of Building Code Standards globally, however Architects could really develop further opportunities with sustainability and protection with the enhancement their designs using SPI Coatings solutions.

Ceramic coatings applied to metal, concrete, wood or other substrates where a reduction in thermal transmission is required. Surface coating applied to substrates in fabrication shop before shipment to site, or applied on site in an approved environment during application and curing.

Environmental benefits of Net Zero Emissions Target Coating

Super Therm® is truly a timely, Energy Star and environmentally-friendly solar heat block coating that addresses both stopping heat and fire protection with minimal effort in application labor, making it ideal for a wider market use. The EPA (Environmental Protection Agency – USA) has recognised the environmental benefits of Super Therm® for reducing energy consumption and resulting pollution from energy consumption. It also creates a net benefit for the reduction of the Urban Heat Island effect.

Apartment building thermal insulation protection

Super Therm® Architectural Specifications

Source: Eagle Coatings

Section One

Product Specifications:

These specifications are provided for convenience and are generic in nature.

1. General

1.1 Description

Ceramic coating applied to metal, concrete, wood or other substrates where a reduction in thermal transmission is required.

Surface coating applied to substrates in fabrication shop before shipment to site, or applied on site in an approved environment during application and curing.

1.2 Quality Assurance

1 Applicator should be certified by the coating manufacturer or distributor.

Finished system to conform to thermal ratings established by:

  • ASTM E1269-01 Standard Test Method for Determining Specific Heat Capacity by Differential Scanning Calorimetry
  • ASTM E1461-01 Standard Test Method for Thermal Diffusivity of Solids by the Flash Method
  • ASTM C236-89 (1993) e1 ”Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded HotBox ” or equivalent.

3 Submit manufacturer’s certification that materials meet or exceed specified requirements.

1.3 Performance Requirements

1 Coating shall limit thermal transfer on all substrates

2 In addition the coating shall meet or exceed the requirements when tested in accordance with ASTM B117, C177, C411, D412, D522, D1653, D1654, D3273-82T, D3274, D4060, E84, E84-89, E96, E903-96, E1269, E1461(92), G53, or equivalents.

3 Coating should be International Codes Council approved.

4 Coating should be an approved Energy Star Partner.

Coating should qualify for LEED (Leadership in Energy and Environmental Design) points.

Coating should carry Factory Mutual approval

Coating may require USDA or CFIA approval or equivalent

Coating may require DNV (Det Norske Veritas) certification

Coating may require IMO (International Maritime Organization) certification

10 Coating may require MSC (Marine Safety Counsel) certification

11 Coating shall exhibit good exterior UV and weathering properties to a minimum of 10 years.

1.4 Product Data

1 Submit data in accordance with Section Two which describes coating material, method of surface preparation, method of application, location of application, environmental condition requirements / limitations and on site touch up and protection.

1.5 Thermal Test Reports

1 Submit documented copies of thermal test reports from certified and independent thermal testing agencies.

2 Submit certified test reports of the following:

  • Coating shall provide a significant reduction of at least 90% in BTU conduction on all substrates when tested in accordance with ASTM E1269-01Standard Test Method for Determining Specific Heat Capacity by Differential Scanning Calorimetry
  • ASTM E1461-01 ”Standard Test Method for Thermal Diffusivity of Solids by the Flash Method” and \ or limit thermal transfer to a rating of 0.31 BTU per square foot / hour / °F or better when applied to the interior side of the substrate and limit thermal transfer to a rating of 0.21 BTU per square foot / hour / °F or better when applied to both sides of the substrate when tested in accordance with
  • ASTM C236-89 (1993) e1 ”Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box” or
  • ASTM C1363 “Standard Method of Test for the Thermal Performance of Building Assemblies by Means of a Hot Box Apparatus”

1.6 Delivery, Storage and Handling

1 Deliver coating materials to place of application in original, unopened container, bearing name of manufacturer and product identification.

2 Store materials off ground, under cover and at a temperature above freezing.

3 Transport and handle any prior coated surfaces with due care to prevent damage.

Section Two

2. Products

2.1 Materials

  • Super Therm® Ceramic Coating manufactured by Superior Products International II, Inc. (SPI Coatings), meeting the requirements of Section One preceding.
  • Super Therm® is a unique combination of high performance aliphatic urethanes, elastomeric acrylics, standard acrylics and resin additives in a water based formula.
  • Super Therm® is designed with four separate ceramic compounds to heat from radiant heat, reflection, conduction and convection.
  • Super Therm® ceramics are not the rough multifaceted type as the one found in other coatings, Super Therm® ceramics are ground to form microscopic spheres. The spherical shape permits the 4 types of ceramics to settle very tight together, not allowing air to interact between the ceramics; thus “plating”.

2.2 Certifications

Super Therm® meets the following ASTM certifications:

B117450 Hour Salt Spray ( Fog )Passed
C177Thermal ConductivityPassed
C236-89 (93)Thermal Transmittance \ ConductancePassed
C411High Temperature SurfacePassed
D412Tensile Properties -.041 thickness = 13,248 psiPassed
D522Mandrel Bend on metal or rubber materials
-1″ (25mm) bend
-1/4″ (6mm) bend
Passed
D1653Water Vapor PermeabilityPassed
D3273-82TFungal ResistancePassed
D3274Fungal ResistancePassed
D4060Abrasion ResistancePassed
E108Standard Test Method for Fire Tests of Roof CoveringsPassed
E84Flame Spread \ Smoke Developed
-Class “A” rating (or Class”I” or Class “1”)
Passed
E84-89aFlame Spread \ Smoke Developed
-Flame Spread Index “0”
-Smoke Developed “0”
Passed
E96Water Vapor TransmissionPassed
E903-96ReflectancePassed
E1269Heat Capacity by Differential Scanning CalorimeterPassed
E1461 (92)Thermal Diffusivity \ Conductivity by Flash Method
– Blocked 91% of Heat BTU Conduction
Passed
G531000 Hours UV ExposurePassed

Super Therm® has other Registrations and Certifications:

Energy Star ProgramApproved Partner
Approved and accepted as an energy partner for saving energy
Passed ASTM E903-96 Reflectivity 80%
Only 1% Reduction in Reflectivity over 3 years
Only 3% Reduction in Reflectivity over 10 years
This test is for Reflectivity only and does not include any insulation abilities
 
ICC (International Code Council)Approved
Formally consolidates approvals for:
BOCA (Building Officials Code Administration)
ICBO (International Conference of Building Officials)
SBCCI (Southern Building Code Congress International)
Division 07 Thermal and Moisture Protection | Section 07200 – Insulation:
– Thermal Insulating Materials Section 723.2 Exposed installations
– Thermal Insulating Materials Section 723.3 Concealed installations
– Interior Finish Section 803.2 Classification
– Insulation Section 604.3 Coverings and linings
– 1998 International Mechanical Code
 
Factory MutualApproved
– Tested and approved for Roofing and all other applications
– Process of Listing
 
USDA (United States Department of Agriculture)Approved
– Letter of Authorization from USDA Product Safety Branch
– Letter of Written Certification as Accepted by USDA from manufacturer
 
CFIA (Canadian Food Inspection Agency)Approved
– Accepted Construction Materials, Packaging Materials and Non-Food Chemical Products
 
DNV ( Det Norske Veritas )Certified
– Passed DNV Audit and DNV Compliance
– Approved for world-wide salt water and maritime use
– Tested Low Flame Spread, no excessive smoke, nor toxic product
 
IMO (International Maritime Organization)Passed
– IMO A. 653 (16) Flame spread for bulkhead, wall and ceiling linings
 
MSC (Marine Safety Counsel)Passed
– MSC.41 (64) Toxic Gas generation using Colorimetric Gas Detector Tubes
– Met all toxic gas requirements
 
NASA (National Aeronautics and Space Administration)Passed
– NASA 8060.1B/C, Test 1 Flammability Test “0” Flame Spread
– NASA 8060.1C, Test 7 Toxic Off-gassing “K” Rating
 
JIS (Japanese Institute of Standards)Passed
– JIS A 5759 Reflectivity Light and Radiation
– Light Reflectivity Ratio 92.2
– Long Wave Radiation ( Infrared ) 99.5
 
China Center for Technical Testing
– GB/T 1771-91 – Resistance to Salt Fog (2000 hours) Passed
– GB/T 1866-88 – Manual Aging (2000 hours)Passed
– GB/T 10834-88 – Resistance to Salt Water (1000 hours)Passed
– GB/T 5219-85 – Adhesion (pulling apart method)4.07Mpa
– GB/T 1733-93 – Boiling Water Immersion8 hours

Section Three

3. Execution

3.1 Protection / Preparation of Substrate

Protect adjacent surfaces and equipment from damage by over-spray, fallout and dusting. Mask adjacent work as required.

Repair any damaged areas first by caulking, patching, sealing, grouting, welding, taping, priming, etc.

Clean substrate to remove dirt, dust, grease, oil, waxy substances, release agents, loose material such as flaking paint or rust or other matter which would affect bond of ceramic insulation coating. Surfaces must be clean, dry and sound before application. High-pressure water blasting with TSP is as effective as light sand blasting in removing loose or old flaking paints or corrosion. As a rule, “a coating is only as good as the surface it covers.” Old paints can remain if bonded solidly to surfaces.

3.2 Environment

Application temperatures range from a minimum of 10°C to a maximum of 65°C but the optimum application temperature is 22°C.

Never apply if it’s raining or there is a chance of rain the day of application. If applied when humidity is high or it rains constantly for 3-4 days after Super Therm® is applied you may notice some bubbling effects on the coating. DO NOT PUNCTURE these bubbles. This is normal as the formula is water based and is absorbing the moisture and, therefore forming bubbles. After the rain stops, the sun will dry out the coating and allow it to cure down naturally. As the sun draws out the moisture, the bubbles will settle down and allow the coating to adhere in its normal dry down without problem.

3.3 Application

1 Super Therm® can bond to metal, wood, masonry and other porous surface substrates, and can be best applied by airless or air pot sprayer, roller and by brush.

2 If rolling, it may take two coats to apply required mils. A 3/4-inch nap roller is best.

3 Spraying requires a .028 – .033 steel carbon tip. Remove all filters from spray equipment before using.

4 Do not apply very thick on a single coat. If thickness is desired, apply in multiple coats. A thick coat will allow the top-coating surface to dry before the bottom thus creating cracks in the coating.

3.4 Coverage

1 Super Therm® is applied at a rate of 95 square feet per gallon. This gives a mil thickness of 17 mils WFT that equals 10 mils DFT being 60% solids by volume.

2 On a horizontal substrate this is easily achieved in one coat using the cross hatch method of up and down and side to side.

On vertical substrates it is possible to apply 17 mils WFT in one coat but it’s easier and better to apply it in 2 coats of 8.5 mils WFT each. This prevents any possible sag by going a little too thick and allows you to cross hatch (side to side then up and down) to achieve a better seal.

3.5 Drying \ Curing Time and Recoat Windows

1 Super Therm® is a waterborne coating which contains no co-solvents and dries by evaporation.

Drying time is generally 1 hour to touch and 2 hours to recoat but these times will vary depending on relative humidity and ambient temperature. More dry time is required in a very cool or damp climate.

3 Super Therm® completely cures is 14 – 21 days again depending on relative humidity and ambient temperature.

4 Super Therm® contains 8% water. Water is a thermal conductor as opposed to a thermal resistor consequently the performance increases over time until all the water has evaporated out of the coating.

3.6 Colors

First and foremost colour of course has an effect on heat build up. The darker the colour the more heat it absorbs.

Unlike paint, which contains 25% – 50% water, Super Therm® only has 8% water for a high quality water based universal tint to work with. Consequently Super Therm® may be tinted to a light pastel or earth tone. The exception to this is GREY because the tint required is black which has a tendency to cover the ceramics and affect the performance. The least desirable colour is black providing heat conductance all the way through the coating.

If a dark colour is desired then the recommendation is to double the mils to 500 microns DFT and topcoat with the dark colour. At least this way the ceramics will throw the absorbed heat back into the topcoat.

4 Even with a pastel colour it’s better to topcoat but then you only need 250 microns DFT of Super Therm®

KW Savings from Super Therm® = Actual Dollar Savings

Globally Accredited Coatings

Connect and Contact SPI

    How did you find out about us?